EasyManua.ls Logo

Kinco CD3 Series - Digital Outputs

Kinco CD3 Series
165 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Kinco FD3&CD3 User Manual
50
5.5.2 Digital outputs
The CD3 motor controller provides 5 digital outputs. The functions of these digital outputs can be configured.
Functions can be set via factory defaults or application default settings after processing the Easy setup menu
(see chapter 4). The functions of the digital outputs can also be freely configured also.
Figure 5-10: Digital output
Function: Click to select the OUT function setting. Click to delete the OUT function setting.
Simulate: Simulates the digital output function logic status 1.
1 means the digital output function is simulated as logic status 1
0 means no impact on the digital output function logic status
Polarity: Inverts the logic status of the digital output function.
1 means Real physical digital output is set to ON by digital output function logic status 1
0 means Real physical digital output is set to ON by digital output function logic status 0
Real: Shows the real digital output status. This is the result of Simulate, Polarity and the logic status of the
selected digital output function via the logic formula:
Real=(Dout_Function_Status OR Simulate) XOR (NOT Polarity)
1 means digital output ON
0 means digital output OFF
Information
More than one digital output function can be selected for a given digital output. The resulting
status is the OR logic of the selected digital output functions.

Table of Contents

Related product manuals