Kinco FD3&CD3 User Manual
The following table lists the digital input functions:
Table 5-2: Digital input functions
Controller enabling
1: Enable controller (Controlword=Din_Controlword(2020.0F) , default value=0x2F)
0: Disable controller (Controlword = 0x06)
Sets the Controlword to reset errors, active edge: 0 -> 1
Operation_Mode selection
1: Operation_Mode=EL.Din_Mode1 (2020.0E), default value = -3
0: Operation_Mode=EL.Din_Mode0 (2020.0D), default value = -4
1: Velocity control loop integrating gain off
0: Velocity control loop integrating gain has been set
Refer to chapter 7 for more information about Kvi.
Positive / negative position limit switch input for “normally closed” limit switches
0: position limit is active, the related direction is blocked
Home switch signal, for homing
Inverts command direction in the velocity and torque mode
Din_Speed Index in the DIN speed mode
Sets the controlword to start quick stop. After quick stop, the controlword needs to be set to
0x06 before 0x0F for enabling (if the enable function is configured in Din, just re-enable it)
Starts homing. Only makes sense if the controller is enabled. The controller returns to the
previous operation mode after homing.
Activates the position command. Controls bit 4 of the Controlword, e.g. Controlword=0x2F-
>0x3F
Gear ratio switch (refer to chapter 5.5.3 for more details)
PI control gain switch (refer to chapter 5.5.4 for more details)
1: Provokes the “Motor temperature” controller error. Can be used to monitor motor
temperature by means of an external temperature switch or PTC sensor. Polarity must be
set according to sensor type.
Fast Capture (refer to chapter 5.5.5 for more details)
For safety reasons, Pre_Enable can serve as a signal for indicating whether or not the entire
system is ready.
1: controller can be enabled
0: controller can not be enabled
Position table condition for position table mode
Start position flow of position table mode
Position table starting index of position table mode
Abort position flow of position table mode