23
3.5 External I/O connectionX4
Figure 3-7: Multi-function connector
Table 3-5: Definition of X4
Pin No.
Signal
Signal name
Description
1
OUT1+
Differential signal output
Open collector output
Max voltage :DC30V
Max current :100mA
3
OUT1-
5
OUT2+
7
OUT2-
9
OUT3
Single end outlet
Max voltage :DC30V
Max current :20mA
11
OUT4
20
OUT5
13
COMO
OUT3, OUT4, OUT5 common port
Digital output common terminal
15
VDD
Internal 24V power output
Internal 24V power output
Voltage range+/-20%,
Max current 300mA
17
VEE
2
COMI
Common end of input signal
Digital input common terminal
4
DIN1
Digital signal input
High level:12.5V-30V
Low level:0-5V
Max input frequency:1KHz
6
DIN2
8
DIN3
10
DIN4
12
DIN5
14
DIN6
16
DIN7

Table of Contents