Kinco FD3&CD3 User Manual
(6071.00)
1: Torque control via AIN1
2: Torque control via AIN2
AIN-MaxTorque factor (unit: mNM/V)
0: Analog_MaxTorque control OFF
1: max. torque control via AIN1;
2: max. torque control via AIN2
For convenience, some new names are used in the formula. The definitions are as follows:
AIN1_in: AIN1 input voltage after filter and offset.
AIN2_in: AIN2 input voltage after filter and offset.
Analog_out: Analog1_out or Analog2_out, depends on wiring and Analog_Torque_Con setting. It’s the result
of AIN real input, filter, offset and deadband.
Final Result:
When Analog_Torque control is ON, target torque[Nm]=Analog_out[V]*Analog_Torque_Factor[Nm/V].
When Analog_MaxTorque control is ON, max. torque[Nm]=Analog_out[V]*Analog_MaxT_Factor[Nm/V].
Example:
Refer to chapter 6.2.1, “Analog speed mode”.
6.4 Position mode (1)
In the position mode, the CD3 motor controller causes the motor to rotate to an absolute or relative position.
The position / velocity command is specified via Target_Position / Profile_Speed or via position table
(Position Table Mode)
Table 6-12: Position mode
Target absolute / relative position
Profile speed for positioning
0x2F->0x3F,
0x4F->0x5F,
0x0F, 0x06
6.4.1 DIN introduction to Location Position
First, when using the DIN position mode, at least one of the DIN position index 0, DIN position index 1, and
DIN position index 2 must be defined in the I/O configuration as a switch signal for the position segment.
DIN position section can be opened through the driver -> control mode >DIN position mode in the
upper computer software menu bar.