Kinco FD3&CD3 User Manual
Figure 3-6 ground schematic
3.3 Power connector (X2)
Table 3-3: Power connector
3.4 RS232 port
(
X3
)
Table 3-3: RS232 port
Control power input L/N
Single phase 200 – 240VAC ±10% 50 / 60Hz, 0.5A
Supply earthing systems: TN-S, TN-C, TN-C-S, TT (not corner earthed).
Drive power input L/N
Single phase 200 – 240VAC ±10%, 50 / 60Hz
750W @7A, 400W @4.5A, 200W @3A, 100W @1.5A
Supply earthing systems: TN-S, TN-C, TN-C-S, TT (not corner earthed).
Information
Short circuit DC+ / RB1 and RB2 if choosing
controller internal braking resistor (power: 10 W)
Note
It is forbidden to use the internal braking resistor
if the average brake power is more than 10 W.
External braking
resistor input
Internal braking
resistor input
External braking
resistor input
U/V/W phase power output for servo motor