Operating Elements
Issue: 08/2012
The xenon lamp is ON. The ventilation runs after when the xenon lamp turns off.
The xenon lamp is OFF.
• Switch on the main switch (position “I”). The fan is running.
• Switch off the main switch (position “0”). The fan is off.
X
The fan runs after (approx. 5 minutes) when the projector and the xenon lamp are
switched off. This thermal switch is operating with a temperature of 60° C.
If the temperature is less than 45° C the switch resets.
The xenon lamp automatically ignites when pushing the start button on the projector
operating panel.
You can manually ignite the xenon lamp by pushing the ignition button.
Do not push this button for more than 0.5 seconds. The xenon bulb can be damaged
if you push for a longer time. If the xenon lamp does not ignite after you have pushed
the button two to three times, the ignition unit or the rectier or the xenon bulb probably
have a defect.