protect. conduct., ground (40) PE gn/ye mains connection 40
mains-phase (60) L1 bk mains connection 60
mains-zero (20) PN bl mains connection 20
+24 V from control board K5-4 2/rd 24 V
24 V GND K5-3 2/bl GND
relay dowser (FU 31) C/O 11 or C/O
relay dowser (FU 32) C/O 14 or C/O
relay RUN 11 gn RUN
relay RUN 14 gn RUN
** interface ext. lm break K-29 rd/wt  ST200 E lm break switch 37
* bridged NC  ST200 E lm break switch
** bridged NC  other lm break
** Interface ext. lm break K2-30 rd/wt  other lm break
spare bl/wt  spare
L1/18 bk  wire 5 LH mains L1 60
N/19 bl  wire 6 LH mains N 20
relay XENON 21 br  wire 1 lamphouse (fan) 60A
relay XENON 24 br  wire 2 lamphouse (hour counter) 60B
relay XENON 14 wt  wire 3 lamphouse 122A
bridged NC  wire 4 lamphouse 122
bridged NC  xenon lamp rectier enable
relay XENON 11 wt  xenon lamp rectier enable
protect. conduct., ground (40) PE  gn/ye LH + SH
* Terminals 11 and 12 are bridged when using the projector without a platter system
** Terminals 12 and 13 and terminals 10 and 13 are bridged when using the projector
with a platter system
Terminal Connections