Operation
Issue: 08/2012
Do not stand too close on rotating lm spools, because clothes, hair or other parts of
your body can get winded up or trapped into the spools.
• Switch on the external power supply for the performance room.
• Switch on the main switch
(position “I”).
$The switch illuminates red.
• Thread the lm (see chapter 5.2).
• Push the button
.
$The projector is running, the ventilation is on, the xenon lamp is on.
• If necessary push the button
on the projector’s operating panel, after the start
leader has run through.
X
Immediate after the projector is switched on you must not manually turn the intermittent
sprocket (e. g. for lm threading) until the projector initialization is completed.
• To stop the projector manually push the STOP button and close the dowser by push-
ing
.
$The dowser closes, the xenon lamp gets off, the projector stops and the ventilation is
on (if the temperature is more than 60° C).
• Switch off the main switch
(position “0”).
$The key lamp turns off.
• Switch off the external power supply for the performance room.
X
Z If you have an emergency stop, push the main switch
(position “0”), to cut the
power.
Z If the lm is run through the projector stops due to the lm break sensor.