EasyManua.ls Logo

Kuka KL 1500-3 - Page 111

Kuka KL 1500-3
151 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
111 / 151Issued: 16.06.2010 Version: MA KL 1500-3 T S 141215 V1 en
14. Options
Procedure 1. Slacken two Allen screws (>>> Fig. 14-4) (3).
2. Slide the position switch towards the cam until there is a distance of 52 mm
(>>> Fig. 14-5) between the cam and the fastening screw (5).
3. Tighten the two Allen screws (>>> Fig. 14-4) (3). To guarantee positive
opening operation, an actuating angle of at least 50° (>>> Fig. 14-5) must
be maintained.
Caution!
If not otherwise specified, all screws must be inserted with Drei Bond 1342
locking agent.
Caution!
It must be ensured that the position switch is securely screwed to the plate.
Slacken the Allen screws until the position switch can only just be shifted.
Fig. 14-4: Adjusting the position switch
1 Position switch 4 Cam
2 Plate 5 Fastening screw
3 Allen screw
Caution!
The distance between the center of the fastening screws on the switch hous-
ing and the upper edge of the cam must not be less than 52 mm.

Table of Contents