EasyManua.ls Logo

Kurzweil PC3LE - Page 285

Kurzweil PC3LE
379 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Keymap and Sample Editing
Editing Samples
12-13
thezeropointofthedisplay(thehorizontallineinthemiddleofthewaveformdisplay.)Though
adjustingthesepointsvisuallyishelpful,alwayslistentothesampleandmakethefinalsettings
basedonwhatsoundsbest.Youllnoticeanaudibleclickinyoursampleloopiftheendsof
the
waveformdonotmeetwheretheloopoccurs.Thecloseryoucangetthetwoendsofthe
waveform,thebetterthesoundqualityofyourloopwillbe.UsingzerocrossingsfortheLoop
andEndparametersmayalsohelpreduceclicksatthelooppoint,seeZero‐
andZero+belowfor
details.
TheEnd(E)parametersetsthepointatwhichthecurrentsamplewillstopplayback.Typically
you’llusethisparametertotrimunwantedsilenceofftheendofasample,althoughyoucanuse
ittoshortenasampleasmuchasyouwant.
NoteOnSaving
Samples:Trimmedportionsofasamplearenotsaved.Trimmedportionsbeforethe
Start(S),orAlternativeSt art(A)points(whicheverhasalowervalue)willbelostuponsaving,and
whicheverparameterhadalowervaluewillhaveavalueofzerothenexttimeitisloaded(values
forall
othersamplepointparameterswillbeadjustedrelatively.)TrimmedportionsaftertheAlternativeStart
(A)orEnd(E)points(whicheverhasahighervalue)willbelostuponsaving.Ifyouwishtosaveacopyof
theoriginaluntrimmedsample,savethetrimmedversionunderadifferent
ID#.Ifyousaveatrimmed
sampleatitsoriginalID#,youcanalwaysrestoretheoriginalversionbydeletingthemodifiedversion
thatyousaved.Todeletea sample,seeOBJECT on page 928,theDeletefunction.
Zoom- and Zoom+
Thesebuttonsincreaseordecreasetheresolutionofthewaveformdisplay,enablingyoutosee
a
largerorsmallerseg m entofthe waveformofthecurrentlyselectedsample.Thetoplineofthe
displayindicatesthezoompositionintermsofafraction—forexample,1/256—whichindicates
thenumberofindividualsampleelementsrepresentedbyeachdisplaypixel.Avalueof1/256
meansthateachpixel
represents256individualsampleelements.Themaximumzoomsetting
of1showsyouaverysmallsegmentofthesample.Theminimumsettingof1/16384showsyou
thelargestpossiblesegmentofthesample.EachpressofaZoomsoftbuttonincreasesor
decreasesthezoombyafactorof4.
Gain- and Gain+
Thesebuttonsincreaseordecreasethemagnificationofthecurrentlydisplayedsample
waveform,enablingyoutoseethewaveformingreaterorlesserdetail.Attheleftofthedisplay,
you’llseethemagnificationsetting,whichisexpressedindBunits.Youcanadjustthe
magnificationfrom48dB(maximum
magnification)to 0 dB.Thisdoesn’taffecttheactual
amplitudeofthesample,onlythemagnificationofitsdisplay.
ThesimplestwaytothinkoftheZoomandGainbuttonsistorememberthattheZoombuttons
controltheleft/rightmagnificationofthewaveform,whiletheGainbuttonscontroltheup/
downmagnification.Neither
buttonhasanyaffectonthesoundofthesample.Youlloftenuse
theZoomandGainsoftbuttonstogethertofocusinonaparticularsamplesegment,then
magnifyittoseeitinclosedetail.
Forexample,youmightwanttozoomouttoviewanentiresamplewaveform,
todecidewhich
segmentyouwanttoedit.Youcouldthenzoomintofocusonaparticularsegment.Onceyou’ve
zoomedin,youmaywanttoboosttheGaintoenableyoutosetanewStart(S)pointwith
greaterprecision,orensurethatyougetasmooth
looptransition.
Zero- and Zero+
PressingtheZero‐orZero+buttonswillsearchleftorrightrespectivelyforthesample’snext
zerocrossing.Azerocrossingisapointwherethesamplewaveformisneitherpositiveor
negative(crossingthehorizontallineinthemiddleofthewaveformdisplay.)Thecurrently
selectedparameter(Start
(S),AlternativeStart(A),Loop(L),orEnd(E))willbesettothispoint
inthesample.S ettingtheseparameterstozerocrossingscanhelpminimizeclicksatthestart,
end,orlooppointofasample.It’sbesttohaveeachofthesepointssetfirstbyadjusting
each
parameterandlisteningtothesample,thenifneededsearchforanearbyzerocrossing.

Table of Contents