2FP/2FY/2FR-4
1-6-36
1-6-14 Replacing the ozone filter B and ozone filter
(1) Replacing the ozone filter B and ozone filter
1. Remove the top cover/face-down output tray.
See page 1-6-7.
2. Remove the right cover. See page 1-6-8.
3. Replace the ozone filter B.
4. Remove the two screws and then remove
the cooling fan motor.
5. Replace the ozone filter.
Figure 1-6-35 Replacing the ozone filter B
Figure 1-6-36
Figure 1-6-37 Replacing the ozone filter
Ozone filter B
Ozone filter
Cooling fan motor
Screw