1-2-1 Drum
Note the following when handling or storing the drum.
When removing the process unit, never expose the drum surface to strong direct light.
Keep the drum at an ambient temperature between 10°C/50°F and 32.5°C/90.5°F and at a relative humidity not higher
than 80% RH. Avoid abrupt changes in temperature and humidity.
Avoid exposure to any substance which is harmful to or may affect the quality of the drum.
Do not touch the drum surface with any object. Should it be touched by hands or stained with oil, clean it.
1-2-2 Installation environment
1. Temperature: 10 - 32.5°C/50 - 90.5°F
2. Humidity: 20 - 80%RH
3. Power supply: 120 V AC, 7.1 A
220 - 240 V AC, 3.8 A
4. Power source frequency: 50 Hz ±0.3%/60 Hz ±0.3%
5. Installation location
Avoid direct sunlight or bright lighting. Ensure that the photoconductor will not be exposed to direct sunlight or other
strong light when removing paper jams.
Avoid extremes of temperature and humidity, abrupt ambient temperature changes, and hot or cold air directed onto the
machine.
Avoid dust and vibration.
Choose a surface capable of supporting the weight of the machine.
Place the machine on a level surface (maximum allowance inclination: 1°).
Avoid air-borne substances that may adversely affect the machine or degrade the photoconductor, such as
mercury, acidic of alkaline vapors, inorganic gasses, NOx, SOx gases and chlorine-based organic solvents. Select a
room with good ventilation.
6. Allow sufficient access for proper operation and maintenance of the machine.
Machine front: 50 mm/19
11
/
16
" Machine rear: 40 mm/15
3
/
4
"
Machine right: 25 mm/9
7
/
8
" Machine left: 25 mm/9
7
/
8
"
Machine above: 30 mm/11
13
/
16
"
a
b
c
a: 300 mm/14
3
/
4
"
b: 345 mm/14
7
/
8
"
c: 390 mm/9
1
/
4
"
Figure 1-2-1 Installation dimensions