FS-6020
1-2-1
1-2-1 Process unit
Note the following when handling or storing the process unit.
• When removing the process unit, never expose the drum surface to strong direct light.
• Avoid abrupt changes in temperature and humidity.
• Avoid exposure to any substance which is harmful to or may affect the quality of the drum.
• Do not touch the drum surface with any object. Should it be touched by hands or stained with oil, clean it.
1-2-2 Toner container
Store the toner container in a cool, dark place. Avoid direct light and high humidity.
1-2-3 Installation environment
1.Temperature: 10 - 32.5°C/50 - 90.5°F
2.Humidity: 20 - 80%RH
3.Power supply: 120 V AC, 10.8 A (U.S.A./Canada)
220 - 240 V AC, 7.2 A (European countries)
4.Power source frequency: 50 Hz ±2%/60 Hz ±2%
5.Installation location
• Avoid direct sunlight or bright lighting. Ensure that the photoconductor will not be exposed to direct sunlight or other
strong light when removing paper jams.
• Avoid extremes of temperature and humidity, abrupt ambient temperature changes, and hot or cold air directed onto
the machine.
• Avoid dust and vibration.
• Choose a surface capable of supporting the weight of the machine.
• Place the machine on a level surface (maximum allowance inclination: 1° ).
• Avoid air-borne substances that may adversely affect the machine or degrade the photoconductor, such as
mercury, acidic of alkaline vapors, inorganic gasses, NOx, SOx gases and chlorine-based organic solvents.
• Select a room with good ventilation.
6.Allow sufficient access for proper operation and maintenance of the machine.
Machine front: 1000 mm/39
3
/
8
" Machine rear: 100 mm/3
15
/
16
"
Machine right: 700 mm/27
1
/
2
" Machine left: 600 mm/23
5
/
8
"
Figure 1-2-1 Installation dimensions
a: 467 mm/18
3
/
8
"
b: 310 mm/12
3
/
16
"
c: 410 mm/16
1
/
8
"
a
b
c