(1) Detaching and refitting the main charger unit
Perform the following procedure when the main charger unit is to be checked or replaced.
Procedure
1. Remove the process unit.
2. Push the claw and remove the cap.
3. While sliding the main charger unit slightly
and then pull it out.
4. Check or replace the main charger unit.
5. Refit all the removed parts.
Figure 1-6-19
Claw
Cap
Main charger unit