FS-6020
1-6-18
1-6-7 Fixing section
(1) Detaching and refitting the fixing unit
Perform the following procedure when the fixing unit is to be checked or replaced.
Procedure
1. Remove the top cover (see page 1-6-2).
2. Remove the left cover (see page 1-6-3).
3. Remove the right cover (see page 1-6-4).
4. Remove the rear cover (see page 1-6-5).
5. Remove one connector from the power
source PWB and one connector from the
engine/high voltage PWB.
6. Remove the two screws and then remove the
fixing unit.
7. Check or replace the fixing unit.
8. Refit all the removed parts.
Figure 1-6-21
Screw
Screw
Fixing unit
Connectors