FS-6020
1-6-29
(3) Detaching and refitting the power source PWB
Perform the following procedure when the power source PWB is to be checked or replaced.
Procedure
1. Remove the top cover (see page 1-6-2).
2. Remove the left cover (see page 1-6-3).
3. Remove the two connectors.
4. Remove the five screws and then the power
source PWB.
*Power source PWB and engine/high voltage
PWB are connected directly with the PWB
connector.
5. Check or replace the power source PWB.
6. Refit all the removed parts.
Figure 1-6-37
Connector
Connector
PWB
connectors
Screws
Screws
Power source PWB
YC9