2J5
1-5-21
(5) Detaching and refitting the fuser thermistor M, fuser thermistor S and thermal cutout
Procedure
1. Remove the fuser unit (See page P.1-5-16).
2. Turn the fuser unit bottom side up.
3. Unlatch two latches and then remove the
cord cover.
4. Unlatch four latches and then remove the
fuser drawer connector.
5. Remove two connectors.
Figure 1-5-28
6. Remove the heat roller (See page P.1-5-19).
7. Remove the screw and then remove the
fuser thermistor S.
Figure 1-5-29
Cord cover
Latch
Latch
Latch
Latch
Fuser unit
Connector
Connector
Fuser drawer
connector
Fuser thermistor S
Screw