2JN
1-4-23
U03400 Polling reception was interrupted because of a mismatch in individual numbers (destination unit is
either of our make or by another manufacturer).
U03500 In confidential polling reception, the specified confidential box No. was not registered in the desti-
nation. Or, in interoffice subaddress-based bulletin board reception, the specified Subaddress con-
fidential box number was not registered in the destination unit. Or, the destination was being
accessed.
U03600 Confidential polling reception was interrupted because of a mismatch in specified confidential box
No. Or, an interoffice subaddress-based bulletin board reception was interrupted because of a mis-
match in the specified subaddress confidential box number.
U03700 Confidential polling reception failed because the destination unit had no confidential polling trans-
mission capability or data was not accumulated in any box in the destination unit. Or, interoffice
subaddress-based bulletin board reception failed because the destination unit had no subaddress-
based bulletin board transmission capability, or data was not stored in any subaddress confidential
box in the destination unit.
U04000 The confidential box specified for confidential transmission was not registered in the destination
unit. Or, in interoffice subaddress-based transmission mode, the specified subaddress box number
was not registered in the destination unit. Or, the destination was being accessed.
U04100 Confidential transmission failed because the destination unit had no confidential capability. Or,
subaddress-based transmission failed because the destination unit had no subaddress-based
reception capability.
U04200 In encrypted transmission, the specified encryption box was not registered in the destination unit.
U04300 Encrypted transmission failed because the destination unit had no encrypted communication capa-
bility.
U044XX Communication was interrupted because of an encryption key error during encrypted transmission
(refer to page 1-4-30 U044XX error code table).
U04500 Encrypted reception was interrupted because of a mismatch in encryption keys.
U05000 In transmission with a specified number, the set number of originals was different from the number
of transmitted originals.
U05100 Password check transmission or restricted transmission was interrupted because the permit ID’s
did not agree with.
U05200
Password check reception or restricted reception was interrupted because the permit ID’s did not match,
the rejected FAX number’s did match, or the destination receiver did not return its phone number.
U05300 The password check reception or the restricted reception was interrupted because the permitted
numbers did not match, the rejected numbers did match, or the machine in question did not
acknowledge its phone number.
U09000 G3 communication was attempted but failed because the destination unit was a G2 machine.
U12000 Relay broadcast was requested from a command station but memory overflowed during reception.
Or, in subaddress-based relay reception, memory overflowed.
U12100 Relay was commanded but memory overflowed in the destination unit (relay station).
U14000 Memory overflowed during confidential reception. Or, in subaddress-based confidential reception,
memory overflowed.
U14100 Memory overflowed in the destination unit during confidential transmission. Or, in interoffice sub-
address-based transmission, memory overflowed in the destination unit.
U19000 Memory overflowed during memory reception.
U19100 Memory overflowed in the destination unit during transmission.
U19200 Memory transmission failed because a decoding error occurred.
U19300 Transmission failed because an error occurred during JBIG encoding.
U19400 Reception failed because an error occurred during JBIG decoding.
Error code Description