114
14 Appendix
Design
Area of application: - IR and UV flame sensors
- Range switchable by means of toggle switch
- IR + UV activated via internal jumper (see figure above).
Frequency range: Flame simulation in 4 frequency ranges
Voltage supply: - Alkaline battery 9 V, 500 mAh
- Automatic switch-off after approx. 5 minutes
- Battery life approx. 3 years
Housing
Design: Cylindrical aluminium housing
Installation: Direct connection through:
- Threaded receptacle for F200K, F300K
- Plug-in receptacle for FFS05, FFS06, FFS07, FFS08,
F100K, F200K
Climatic range
Protection class:
1
- IP54
Protection class: Protection class III
Weight: 0.52 kg/1,14 lb