3-40 Developed for Training Purposes Leerjet 35/36
October 2001
CAE SimuFlite
Engine Synchronizer
The engine synchronizer must be off for takeoff, landing, and
single-engine operation.
Starter Cooling Periods
If engine does not start, adhere to the following cooling periods
between start attempts.
This cycle may then be repeated.
Oil Temperature
Maximum Oil Temperature . . . . . . . . . . . . . . . . . . . . . . . 140°C
Approved Oils
The following Type II oils conforming to Honeywell Specification
EMS 53110, are approved for use:
Engines modified by AlliedSignal Service Bulletin TFE731-72-
3596 require specific oil use. Refer to the Honeywell Engine
Light Maintenance Manual for engine oil service instructions.
Information shown in italics is not included in the AFM Limitations chapter.
After Start Attempt Wait
1 1 Minute
2 1 Minute
3 15 Minutes
4 1 Minute
5 1 Minute
6 1 Hour
n
Aeroshell/Royco
Turbine Oil 500
n
Aeroshell/Royco
Turbine Oil 560
n
Castrol 5000
n
Exxon (Enco/Esso)
2380 Turbo Oil
n
BP Turbo Oil 2380
n
Exxon 2197
n
BP Turbo Oil 2197
n
Mobil Jet Oil II
n
Mobil 254