Leerjet 35/36 Developed for Training Purposes 3-41
October 2001
Limitations
Engine Operating Limitations
1 Normal oil operating temperatures for all conditions.
2 If a takeoff ITT of 870°C or more is attained for more than 10 seconds, or 930°C is attained or exceeded, refer to the engine service manual for corrective action.
3 If start ITT is exceeded, abort start and refer to engine maintenance manual.
Condition Time Limit ITT Temp. °C N1% RPM
Start
—
860
3
— —
Indication
Within 10 Secs.
After Lightoff
30 to 140
Idle — — — — 25 to 46 30 to 140
Takeoff
5 Minutes
860
2
See chart in
AFM Section V
100 38 to 46 30 to 140
Recommended-
Maximum
Cruise
Unrestricted 795 — — 38 to 46 30 to 140
Maximum
Continuous Unrestricted 832
See chart in
AFM Section V 100 38 to 46 30 to 140
Overspeed
Transient
1 Minute — 100 to 103 100 to 103 55 30 to 140
Overspeed
Transient
5 Seconds — 103 to 105 103 to 105 — 30 to 140
Overspeed — — Over 105 Over 105 — 30 to 140
CAUTION: Mixed oil use in an ASE SB TFE731-72-3596 modified engine is
limited to 25 operating hours. Any of the Type II oils conforming to Honeywell
EMS 53110 listed (page 3-40) are approved for mixed oil use. Refer to the Hon-
eywell Engine Light Maintenance Manual for corrective action.