3. For the selected Source, press the Mode option button and select a
Trigger Type (Edge, Pulse, Slope, or Video).
4. For the selected trigger type, set the trigger options.
5. Press the Setup option button to display the Trigger Setup menu.
You can use the Trigger Setup menu to select a coupling mode and
define a Holdoff value. Coupling modes comprise DC, AC, HF Reject,
and LF Reject. Turn the Adjust front panel knob to set the Holdoff
value.
Analyzing Waveforms
Waveform Measurements
Measuring with Cursors
Cursors are important tools that aid you in measuring signal values.
Cursors are boundary markers you can move across the grid. Use cursors
to make fast, accurate measurements and eliminate guesswork.
There are three cursor measurement modes:
1. Manual - displays two horizontal parallel cursors or vertical parallel
cursors to measure voltage or time, respectively. Voltage cursors
appear as horizontal lines on the display and measure the vertical
parameters.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the LeCroy WaveAce series and is the answer not in the manual?

LeCroy WaveAce series Specifications

General IconGeneral
BrandLeCroy
ModelWaveAce series
CategoryTest Equipment
LanguageEnglish

Related product manuals