Do you have a question about the LeCroy WaveAce series and is the answer not in the manual?
Channels | 2 or 4 |
---|---|
Vertical Resolution | 8-bit |
Input Coupling | AC, DC, GND |
Power Supply | 100-240 VAC, 50/60 Hz |
Sample Rate | 2 GS/s |
Display | 800 x 480 |
Input Impedance | 1 MΩ |
Timebase Range | 5 ns/div to 50 s/div |
Trigger Types | Edge, Pulse Width, Video, Slope |
Connectivity | USB host, USB device |
How to get help and support for your WaveAce oscilloscope.
Explanation of safety symbols used in the manual and on the instrument.
Information on the instrument's cooling system and ventilation requirements.
Details on the power usage of the oscilloscope in different modes.
Instructions for connecting the oscilloscope to power and ground.
Guidelines for cleaning the oscilloscope's exterior safely.
What to do if the instrument's protection is suspected to be impaired.
Overview of the buttons and knobs on the oscilloscope's front panel.
Step-by-step guide to turning on the WaveAce oscilloscope.
Explanation and usage of the Intensity/Adjust knob for various functions.
Details on adjusting vertical settings like Volts/Div and channel selection.
Procedure for compensating the oscilloscope probes for accurate measurements.
How to set the attenuation factor for different probes.
Instructions on how to display waveforms from channels.
How to select the input coupling mode (DC, AC, GND) for signals.
How to apply digital filters like LPF and HPF to signals.
Explanation of different sampling modes like Sampling, Peak Detect, Average.
Details on the three basic acquisition modes available.
Steps for acquiring single or continuous waveforms.
How to use window zone to zoom in on waveform segments.
Overview of the different trigger types available on the oscilloscope.
Configuration steps for edge triggering on waveforms.
Introduction to tools for measuring waveform parameters.
How to use cursors for accurate waveform measurements.
Overview of standard math functions like add, subtract, multiply, divide, and FFT.
How to save and recall oscilloscope panel settings.
Procedure for saving the current oscilloscope configuration.
Steps to recall saved setups from the oscilloscope's internal memory.
Steps to recall saved setups from a USB memory device.
Instructions for saving waveforms to internal memory or USB devices.
Procedure for saving waveforms to the oscilloscope's internal memory.
How to recall saved waveforms from internal memory.
How to recall saved waveforms from a USB memory device.
Steps to save waveform data into a comma-separated value (.CSV) file.
Accessing and navigating the oscilloscope's utility menu.
First page of utility functions including System Status and Sound.
Viewing the oscilloscope's hardware and software configuration.
First page of print setup options including Ink Saver, Layout, and Paper Size.
Instructions for downloading and installing system software updates.
First page of Pass/Fail test setup, enabling the function and selecting source.
First page for setting up the Pass/Fail test mask parameters.
Detailed technical specifications for the WaveAce oscilloscope.
Information on compliance certifications such as CE, UL, and cUL.
How to find and contact LeCroy for sales and technical support.