Test and Adjustment 9-1
D-H001.0609EN
9. TEST AND ADJUSTMENT
9.1 Test the Save-Life Switch
1. On the CRS+, make sure a main cleaning is not being prepared.
2. If a main cleaning is being prepared, wait until the main cleaning is complete before you continue this
procedure.
3. Take the milking robot out of operation with the X-link (page 6-5).
4. Use a screwdriver to turn the locks (1) and (2) 90° counterclockwise to release the cover of the multiple
function box.
5. Pull the bottom edge of the cover toward you to open the multiple function box.
6. Make sure the back-up batteries in the multiple function box are connected.
7. Press the test-button of the save-life switch.
8. If the save-life switch does not operate immediately, replace the save-life switch.
9. Set the save-life switch to the up position.
10. Pull the cover down to close the multiple function box.
11. Use a screwdriver to turn the locks (1) and (2) 90° clockwise.
12. If necessary, start the milking robot (page 6-2).
13. Put the milking robot in operation with the X-link (page 6-3).