6-2 Operating Instructions
D-H001.0609EN
6.2 Calibrate the Robot Arm
1. Select the pop-up window: Calibration robotarm.
2. Select [
Start].
3. Make sure:
The robot arm moves up, out, up again and then forward to the limits of all the cylinders
The robot arm stops at the fully forward position.
4. If all the cylinders move to their limits, select [
Accept] and make sure the robot arm moves to the home
position.
5. If all the cylinders do not move to their limits, select [
Stop] and do steps 2 thru 4 again.