5.2308.8512.0 B
TEST AND ADJUSTMENT 7-13
1. Go to the page Data Entry > Settings.
2. Select tab 'Feedings'.
3. Select tab 'Feed type'.
4. Select the applicable feed type.
5. Select the field 'Feed speed'.
6. Select the applicable 'Field Label'.
7. Enter the 'Feed speed'.
8. Click on button [Save].
7.9 Adjustments with the Service Interface
7.9.1 Calibrate the Valves with the Service Interface
1. Open a web browser on a PC connected to the T4C network.
The IP-address for the first concentrate feeder is 10:4:1:11 for the
second 10:4:1:12 and so on.
2. Enter the IP-address: HTTP://10.4.1.xx:8080 (xx=11 or 12 and so on) in
the address field of the web browser.
3. Select field 'CalibrateTagsActive'.
4. Select ON.
5. Select 'Cal. Tag1'.
6. Activate the dosing unit with a cow tag.
7. Make sure the dosing unit supplies 10 portions of concentrate.
8. Use a balance to measure the weight of the feed.