5.2308.8512.0 B
INSTALLATION 5-9
Figure 20. Square the angles
KEY:
1. Front portal
A: Distance between front side of side fence and opposite bracket
B: Distance between front side of side fence and opposite bracket
5.3.4 Install the Portals on the Floor
Parts
Expander bolt M12×120×80.
Installation
Use the supplied expander bolts on concrete floors, otherwise use
suitable M12 installation hardware.
1. Install the front and rear portal on the floor, at least 3 cm (1.2 in) from
the wall (wall to outside pipe).