5.2308.8512.0 B
5-34 INSTALLATION
3. Connect the inner wire to the + antenna connector (16) on the Velos
box.
5.4.3 Connect the 230 VAC Power Supply Cable
1. Install a power supply cable from the nearest 230 V power supply to
the concentrate feeder.
2. Feed the power supply cable into the control box.
3. If necessary, strip the cable and the cable wires.
4. Connect the cable wires of the power supply cable:
Protective Earth wire (yellow/green) to (17) (see figure 40 on page
5-32).
Neutral (blue) to (21).
Phase (brown or black) to (21).
5. Use cable-ties to attach the cable to the frame.
5.4.4 Prepare the Network Cable
Use a Network Switch if the length of the network cable is more than
100 m (109 yd).
5.4.4.1 Introduction
A type 1 or a type 2 network connector can be installed to a network
cable.
Figure 42. Network Connector Types
KEY:
1. a) Type 1 network connector (T-568A) - 1. b) Type 1 network connector (T-568B) - 2.
Type 2 network connector (T-568A)
5.4.5 Install a Type 1 Network Connector
Special tools
Ethernet crimping tool.
Preparation