INSTALLATION 5-35
1. Make sure the network cable is of type S-FTP 200MHz CAT5e.
2. Cut a piece of network cable to the correct length.
3. Feed the network cable into the control box.
Installation
1. Install the connector cover and the cap on the network cable (1) (see
figure 43 on page 5-36).
2. Remove approximately 5 cm (1.96 in) of the insulation (2) of one side
of the cable.
3. Slide the screen backward (3).
4. Fold the wire backward (4).
5. Peel the metal shield from the cable (4).
The inside of the metal shield is covered with an insulating film
(often blue colored). If the metal shield is turned backward, the cable
cannot make a ground connection with the connector.
6. Remove the plastic shield from the cable (5).
7. Splice the wires (6) and (7).
8. Sort the wires by color according to one of the tables.
A Type 1 Network Connector can be configured accordingly a Type A
or Type B wiring scheme. Use the same scheme (A or B) on both cable
ends.
T-568A T-568B
1
Green/White
1 1
Orange/White
1
2 Green 2 2 Orange 2
3
Orange/White
3 3
Green/White
3
4
Blue
4 4
Blue
4
5
Blue/White
5 5
Blue/White
5
6 Orange 6 6 Green 6
7
Brown/White
7 7
Brown/White
7
8
Brown
8 8
Brown
8
9. Cut the wires to a length of 1.3 cm (0.51 in) (9).
10. Put the wires and the cable fully in the RJ-45 plug (10).
11. Make sure the wire is on the left or right side of the plug (11).
12. Put the plug in the crimp tool until it clicks (12).
13. Squeeze the crimp tool until it clicks (13).
14. Push the plug tab and remove the plug from the crimp tool (14).
15. Remove the shielding and the wire (15).