5-38 INSTALLATION
Figure 44. Install a type 2 network connector
5.4.7 Install the Network cable on an Earthing Clamp
1. Remove one of the earthing clamps (8) (see figure 40 on page 5-32).
2. If the concentrate feeder has no (optional) network switch:
1. Connect the network connector to the ADS3830 PCB (3).
2. Mark the position of the earthing clamp on the network cable.
3. Remove the network connector from the ADS3830 PCB.
3. If the concentrate feeder has an (optional) network switch:
1. Connect the network connector to the network switch (12).
2. Mark the position of the earthing clamp on the network cable.
3. Remove the network connector from the network switch.