5.2308.8512.0 B
TEST AND ADJUSTMENT 7-5
4. Use buttons [
] or [ ] to change the value.
5. Push soft button [OK] to confirm. After a few seconds you return to
the menu ‘Settings’.
7.4.7 Adjust the Portion Size
Block the cow traffic to the concentrate feeder before you do
this procedure.
Use the E-Link manual controller for this procedure.
1. Make sure the feed bin is empty.
2. Use the E-Link to drop five portions for feed type 1 (see page 7-6).
3. Remove the feed from the feed bin.
4. Use a balance to weigh the feed.
5. Calculate the portion size by dividing the total weight by five.
6. Set the portion size for feed type 1 (see page 7-4).
7. Repeat the procedure for other feed types.
7.4.8 Clear all Tables
Block the cow traffic to the concentrate feeder before you do
this procedure.
Use the E-Link manual controller for this procedure.
1. In the main menu of the E-Link, select ‘Setup’ and push button[
].
2. Select 'Clear All Tables' and push button [
]. The E-Link displays the
message "Remove Local Data!!!".
3. Push soft button [OK] to confirm. After a few seconds you return to
the menu 'Setup'.
7.5 Test the Operation of the Cosmix P
7.5.1 Test the Time Setting
Block the cow traffic to the concentrate feeder before you do
this procedure.
Use the E-Link manual controller for this procedure.
1. In the main menu, select 'Testing' and push button [
].
2. Select 'Time' and push button [
].
3. Make sure the values are correct.
1. If the settings are correct, push button [
].
innovators in agriculture