5.2308.8512.0 B
3-2 SPECIFICATIONS
Electrical power
100 - 240 VAC.
Earthing
Earthing of the concentrate feeder must comply with current earthing
regulations for barns (obey local rules and standards).
The earth wire must be connected to the earth point.
An authorized electrician must approve the final electrical installation
(including earthing) and supply an official report that is given to the
Lely service provider before the installation is used.
Warranty on electronics will not be given if the earthing is not correctly
installed.
T4C network
Network connection:
LAN CAT.5e Network cable, S-FTP 200 MHz (foil-screened twisted pair
with overall screening (copper braiding)) with steel RJ-45 connector.
Maximum cable length: 100 m (109 yd) (use a switch if the distance is
more than 100 m (109 yd)).
An optional network switch can be installed in the control box to connect
more than one concentrate feeder to the network.