S002
CAUTION:
The power-control button on the device and the power switch on the power supply do not turn off the
electrical current supplied to the device. The device also might have more than one power cord. To
remove all electrical current from the device, ensure that all power cords are disconnected from the
power source.
About this task
Attention:
• Read
“Installation Guidelines” on page 29 and “Safety inspection checklist” on page 30 to ensure that you
work safely.
• Power off the server and peripheral devices and disconnect the power cords and all external cables. See
“Power off the server” on page 34.
• Remove any locking device that secures the server, such as a Kensington lock or a padlock.
• Place the server on its side with the cover up.
Procedure
Step 1. Make preparation for this task.
a. Remove the server cover. See
“Remove the server cover” on page 135.
Attention: The heat sink and processor could be very hot. To avoid burning yourself, wait for a
few minutes after turning off the server before you remove the server cover.
b. Disconnect the cables from the drive assembly.
Step 2. Remove the bay 2+bay 3 drive cage assembly from the chassis.
a.
Rotate the handle on the bay 3 drive cage.
b.
Lift the bay 2+bay 3 drive cage assembly out from the chassis.
62
ThinkSystem ST45 V3 User Guide