Electrical installation − EMS version
Devices in a power range of 0.75 ... 4 kW (3/PE AC 400 V)
Terminal assignment of the power connections
7
126
EDS84DPS424 EN 5.0
Connection of external brake resistor
X20 − connection of external brake resistor (optional)
Pin Connection Description Data
Type Q5, sockets
E84DWX0202
1 RB2
Brake resistor max. 2.5 mm
2
2 RB1
3 T1
In preparation
Brake resistor temperature monitoring
5 T2
4 n. c. Not assigned
PE PE conductor