Device description
Leuze electronic RSL 430 14
All safety sensors of the RSL430 series are equipped as follows:
• Laser scanner with the range class S, M, L or XL:
Operating range
class
Operating range [m]
S 3.00
M 4.5
L 6.25
XL 8.25
• 24-digit alphanumerical display
• Integrated electronic spirit level for aligning the safety sensor
• LED indicator
• USB interface
NOTICE
Ä Use the USB connection only temporarily for configuration or diagnosis of the safety sensor.
Ä For permanent connection, connect the safety sensor to the Ethernet connection of the con-
nection unit.
• Connection unit:
• Configuration memory
• Ethernet connection for communication and configuration with the PC/laptop
• Electrical connection to the machine via connection cable
3.1 Device overview
The following table provides an overview of the possible uses, features and functions of the RSL400 safety
sensors.
Tab.3.1: Device overview
RSL410 RSL420
RSL425
RSL430 RSL440
RSL445
Stationary danger zone guarding x x x x
Mobile danger zone guarding x x x x
Access guarding x x x x
Point of operation guarding x x x x
Safety-related switching outputs
Protective functionA
Protective functionB
1 OSSD pair
x
-
1 OSSD pair
x
-
2 OSSD pairs
x
x
2 OSSD pairs
x
x
Signal outputs Up to 3 Up to 4 Up to 9 Up to 9
Configurable signal outputs x x x x
Number of changeover-capable pro-
tective/warning field pairs
1 10 10+10 100
E-stop linkage - x x x
Four field mode (quads) x x x x
Internal safe time delay - - x x
Measurement data output optimized
for vehicle navigation
- Only RSL425 - Only RSL445
USB interface - x x x