Configuring the safety sensor
Leuze electronic RSL 430 81
NOTICE
The device manager (DTM) starts without querying the access level of the user. During commu-
nication with the safety sensor, the safety sensor does however query the access level of the
user. To change the access levels, see chapter 9.9 "Selecting access level".
9.4 Configuring protective function
Prerequisites: The safety distance, additional distances and protective field dimensions and contours have
been determined according to the mounting position (see chapter 7.1.1 "Calculation of safety distanceS").
Ä In the initial screen, click the CONFIGURATION tab.
ð The CONFIGURATION menu opens with the options:
• Administration
• OSSDs
If the OSSDs option is selected in the CONFIGURATION menu, the Protective function A option is
displayed, if the One protective function function mode is selected. In the Two protective functions
function mode, the options Protective function A and Protective function B are displayed.
• Changeover order
The Changeover order option is only displayed if more than one protective/warning field pair is cre-
ated (see chapter 9.4.4 "Creating and configuring protective/warning field pairs").
• Outputs
• Other
9.4.1
Creating simple safety configuration
To create a safety configuration for simple commissioning, you must first perform five configuration steps to
access the editor used for defining the contours of the protective and warning fields.
By clicking [Next], you can proceed to the next configuration step without selecting the corresponding op-
tion in the CONFIGURATION menu.
If you make changes to the default settings in a configuration step, first click the [Confirm] button and then
[Next].
Ä Administration
Ä OSSDs
Ä Protective function A
Ä Bank A1
Ä Outputs
9.4.2
Entering administration parameters
Ä In the CONFIGURATION menu, click the Administration option.
ð The ADMINISTRATION dialog box opens.
Ä In the input fields, enter the device data and the project data for the configuration project.
9.4.3
Activating protective function and contactor monitoring
Ä In the CONFIGURATION menu, click the OSSDs option.
ð The OSSDs dialog box opens.
Ä In the FUNCTION MODE list, select the protective function of the safety sensor.
ð The Protective functionA option is shown in the CONFIGURATION menu.
ð The Protective functionB option is shown in the CONFIGURATION menu if Two protective functions
was selected in the FUNCTION MODE list.
NOTICE
The changeover-capable protective/warning field pairs for the selected protective function are
defined in configuration banks.