Testing
Leuze electronic RSL 430 95
11.3.1
Checklist – periodically by the operator
NOTICE
Ä If you answer one of the items on the check list with no, the machine must no longer be op-
erated (see chapter 11.1.1 "Checklist for integrator – to be performed prior to the initial start-
up and following modifications").
Tab.11.2: Checklist – regular function test by trained operators/persons
Test at least: Yes No
Are safety sensor and connectors securely mounted and free of obvious signs of damage,
changes or tampering?
Were obvious changes made to access or entry possibilities?
Test the effectiveness of the safety sensor:
1. The LED1 and LED6 on the safety sensor must illuminate green (see chapter 3.4
"Display elements").
2. Interrupt the protective field using a suitable opaque test object (see figure).
Checking the protective field function with test rod
Do the LED1 and LED6 on the safety sensor illuminate constantly red while the protec-
tive field is interrupted?
Tab.11.3: Checklist – regular function test by trained operators/persons
When possible, test during running operation: Yes No
Protective device with approach function: during machine operation, the protective field is
interrupted with the test object – are the obviously dangerous machine parts stopped with-
out noticeable delay?
Protective device with presence detection: the protective field is interrupted with the test
object – does this prevent operation of the obviously dangerous machine parts?