Device description
Leuze electronic RSL 430 16
3.2 USB connection
The safety sensor features a Mini-B type USB socket as a service interface for configuration and diagnosis.
NOTICE
Ä Use the USB connection only temporarily for configuration or diagnosis of the safety sensor.
Ä For permanent connection, connect the safety sensor to the Ethernet connection of the con-
nection unit.
NOTICE
Ä After use, seal the USB connection using a protection cap. Make sure that the protection
cap is felt to engage when sealing. The IP degree of protection specified in the technical
data is only achieved when the protection cap is closed.
3.3 Connection unit
The safety sensor is mounted, connected and aligned using the connection unit.
M5 2x
2
1
1 Connection cable, connection to the machine
2 M12 socket, D-coded, Ethernet communication connection
M5 Connection for functional earth with M5x10 self-cutting/self-tapping (gas tightness) and ground strap
Fig.3.2: Device overview, connection unit
Functions of connection unit:
Attachment point for mounting, either directly or using an optional mounting system.
When devices are swapped out, the connection unit remains mounted and aligned.
EMC wiring for signal inputs/outputs and supply using connection cable
Safety sensor Connection unit Connection
RSL430 CU429-y
y=5000, 10000, 25000
Connection cable, 29-wire
5m, 10m, 25m
Connector bushing and EMC for the Ethernet TCP/IP communication and configuration interface to the
PC/laptop
Memory for the configuration files and automatic parameter transfer in the event of device swap-out
Quick-release connection to the scanner unit (see Quick Start Guide) for easy device swap-out