Configuring the safety sensor
Leuze electronic RSL 430 82
Ä In the Switch off delay time input field, select the internal safe time delay for switching off the OSSD-B
outputs if One protective function was selected in the FUNCTION MODE list.
Ä In the CONTACTOR MONITORING list, activate the contactor monitoring of the safety sensor:
• EDM OSSD A
• EDM OSSD B
• E-Stop
• OSSD linkage
NOTICE
The activated contactor monitoring (EDM) is assigned to indication signal outputs EA1 and/or
EA2. These signal outputs are thus disabled for the configuration of the signal outputs.
Ä Click the [Confirm] button.
9.4.4
Creating and configuring protective/warning field pairs
The changeover-capable protective/warning field pairs for the selected protective function are defined in
configuration banks. The configuration banks are shown in the navigation tree of the configuration menu as
"Bank", e.g. Bank A1.
Configuring protective/warning field pairs for tow protective functions
NOTICE
Configuration of the protective and warning field pairs is described for the One protective func-
tion function mode (Protective functionA). If you have selected Two protective functions as the
function mode, you must also configure the banks and field pairs for Protective functionB follow-
ing the described procedure.
Creating banks
Ä In the CONFIGURATION menu, click the Protective functionA option.
ð The PROTECTIVE FUNCTIONA dialog box opens.
Ä Enter the description of the protective function in the input field.
Ä In the CONFIGURATION menu, right-click the Protective functionA option.
Select Add configuration bank.
ð The Add bank dialog box opens.
Ä In the Bank list, select the number of the bank and click the [Add] button.
When you have added all banks for the protective function, click [Close].
ð The Bank[x] option is shown for each added bank under Protective functionA in the CONFIGURA-
TION menu.
Configuring banks
The resolution for hand, leg or body detection, the response time and start-up behavior of the safety sensor
and the field pair changeover for the protective/warning field pairs are configured via the banks.
NOTICE
For resolution, response time and AGV speed, select the values that you used for calculating
the safety distances and additional distances for the application assigned to the configuration
bank.
Ä In the CONFIGURATION menu, select the bank the configuration of which you want to define.
ð The RESOLUTION, RESPONSE TIME, START-UP BEHAVIOR and EXTENDED OUTPUT SIGNALS
dialog boxes are displayed.