Electrical connection
Leuze electronic RSL 430 69
8.1 Electrical supply
see chapter 15.1 "General specifications".
Functional earth
NOTICE
Always connect the housing of the safety sensor to functional earth or ground!
Ä The housing of the safety sensor must always be connected to earth (functional earth) or
machine/vehicle ground.
Ä If the safety sensor is attached to a non-conductive material (e.g. a concrete wall), the hous-
ing of the safety sensor must be earthed.
Factory recommendation: Functional earth via a ground strap/braid (low impedance for RF).
Connection points for self-tapping screws used for the ground connection are provided and labeled on
the bottom of the connection unit (see chapter 8.3 "Connection unit CU429").
Functional grounding via the shield of the connection cable.
For grounding, the shield of the connection cable in the switch cabinet must be connected to earth or
machine/vehicle ground.
NOTICE
Make sure that potential equalization is provided!
Ä If the housing of the safety sensor or the mounting bracket – despite being mounted on a
non-conductive material – is connected to metallic parts (even temporarily), you must ensure
that the appropriate potential equalization is provided between the switch cabinet and hous-
ing potential; e.g. by grounding the Ethernet connection.
8.2 Interfaces
The safety sensor has the following interfaces:
Interface for connection with the control system
Ethernet interface for communication with PC or laptop
USB interface for communication with PC or laptop
Tab.8.1: Interfaces
Interface Type Function
Control Connection cable, 29-wire Power supply
Switching lines and signal lines
Communication M12 – RJ45 Configuration interface and data interface:
Parameter configuration
Protective field definition and warning field definition
Data transmission and measurement value transmis-
sion
Diagnosis
Communication USB2.0 mini-B socket Configuration interface and diagnosis interface:
Parameter configuration
Protective field definition and warning field definition
Diagnosis
NOTICE
Ä Use the USB connection only temporarily for configuration or diagnosis of the safety sensor.
Ä For permanent connection, connect the safety sensor to the Ethernet connection of the con-
nection unit.
The control cable is permanently attached to the connection unit. A protection cap on the connection unit
protects the communication interface when no PC is connected.