EasyManua.ls Logo

Leuze electronic RSL 430 - Connection Cable, Control

Leuze electronic RSL 430
127 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Electrical connection
Leuze electronic RSL 430 70
8.2.1
Connection cable, control
The safety sensor is equipped with a 29-wire connection cable.
Tab.8.2: Connection cable, control
Core color Signal Description
White RES1 Start/restart input, protective functionA
Acknowledgment
Brown 24V Supply voltage
Green EA1 Contactor monitoring OSSDA
Alternatively: State signaling, configurable
Yellow A1 Output signal
State signaling, configurable
Gray OSSDA1 Safety-related switching output, protective functionA
Pink OSSDA2 Safety-related switching output, protective functionA
Blue 0V (GND) Supply voltage ground
Red MELD Output signal
State signaling, configurable
Black F1 5 function inputs for field pair changeover, protective functionA
Violet F2
Gray/pink F3
Red/blue F4
White/Green F5
Brown/Green SE1 Linkage input (E-Stop, OSSD – external device)
White/Yellow SE2 Linkage input (E-Stop, OSSD – external device)
Yellow/Brown A2 Output signal
State signaling, configurable
White/Gray A3 Output signal
State signaling, configurable
Gray/Brown A4 Output signal
State signaling, configurable
White/Pink EA2 Contactor monitoring OSSDB
Alternatively: State signaling, configurable
Pink/Brown EA3 Input/output signal, configurable
White/Blue EA4 Input/output signal, configurable
Brown/Blue F6 5 function inputs for field pair changeover, protective functionB
White/Red F7
Brown/Red F8
White/Black F9
Brown/Black F10
Gray/Green RES2 Start/restart input, protective functionB
Acknowledgment
Yellow/Gray OSSDB1 Safety-related switching output, protective functionB
Pink/Green OSSDB2 Safety-related switching output, protective functionB

Table of Contents

Related product manuals