EasyManua.ls Logo

Leuze electronic RSL 430 - Suitable Mounting Locations; Mounting the Safety Sensor

Leuze electronic RSL 430
127 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Mounting
Leuze electronic RSL 430 51
7.1.2
Suitable mounting locations
Area of application: Mounting
Tester: Technician who mounts the safety sensor
Tab.7.1: Checklist for mounting preparations
Check: Yes No
Is the safety distance to the hazard location maintained?
Has the scanning angle of the safety sensor as given on the marking/template on
the top of the sensor been taken into consideration?
Can the point of operation or the danger zone only be accessed through the pro-
tective field?
Have measures been taken to prevent the protective field from being bypassed by
crawling under?
Is stepping behind the protective device prevented or is mechanical protection
available?
Can the safety sensors be fastened in such a way that they cannot be moved and
turned?
Is the safety sensor accessible for testing and replacing?
Is it impossible to actuate the reset button from within the danger zone?
Can the entire danger zone be seen from the installation site of the reset button?
NOTICE
If you answer one of the items on the checklist with no, the mounting location must be changed.
7.1.3
Mounting the safety sensor
NOTICE
Detailed information on mounting the safety sensor can be found in the document "Quick Start
Guide RSL400".
Proceed as follows:
Ä Calculate the necessary safety distance and determine the required additional distances for your appli-
cation.
Ä Determine the mounting location.
Observe the information regarding the mounting locations; see chapter 7.1.2 "Suitable mounting loca-
tions"
Ensure that machine parts, safety guards or covers do not impair the safety sensor's field of vision.
Make sure that the scanning range of the safety sensor is not limited. To mount the safety sensor tak-
ing the scanning range into consideration, a template must be attached to the top cover of the safety
sensor.

Table of Contents

Related product manuals