Functions
Leuze electronic RSL 430 34
5.2.3
One protective function – four field mode
The safety sensor monitors one protective field and three warning fields.
Monitoring is performed together for the field pairs of protective functionA and protective functionB. If, for
example, the control system is monitoring field pair A1.1 for protective functionA, field pair B1.1 for protec-
tive functionB is also monitored.
A1.1P
B1.1P
A1.1W
B1.1W
1
2
3
4
1 Protective function A: protective field
2 Protective function B: protective field
3 Protective function A: warning field
4 Protective function B: warning field
Fig.5.1: Four field mode
If the protective field of protective functionA is violated, safety-related switching outputs OSSD-A switch.
If the protective field of protective functionB is violated, the indication signal B-CLEAR is generated – the
safety-related switching outputs do not switch.
The signals are assigned to the switching outputs via the configuration and diagnostics software (CONFIG-
URATION > Outputs; see chapter 9 "Configuring the safety sensor").
Tab.5.3: Example: Assignment of signals to switching outputs
Logic signal Electrical switching output Description
OSSDA Safety-related switching outputs OSSDA Protective functionA: protective field violation
B-CLEAR Switching output MELD – not safe Protective functionB: protective field violation
A-WF-VIO Switching output A1 Protective functionA: Violation of warning field
B-WF-VIO Switching output EA1 Protective functionB: Violation of warning field