Electrical connection
Leuze electronic RSL 430 74
1
2
3
4
5
6
7
8
9
10
1 Operating voltage [V]
2 Cable length [m]
3 ILoad = 0A
4 ILoad = 250mA
5 ILoad = 500mA
6 ILoad = 750mA
7 ILoad = 1A
8 ILoad = 1.25A
9 ILoad = 1.5A
10 ILoad = 1.65A
Fig.8.4: Diagram for estimating the voltage drop on the supply line
Maximum load current: 1.65A with RSL400 cable
1mm
2
/AWG18 for supply and 0.14mm
2
/AWG26 for signals
NOTICE
Cable length and cable resistance with OSSD linkage!
When using the OSSD linkage function, observe the specifications of the upstream device for
the cable length and for the maximum permissible cable resistance (see chapter 5.13.2 "Linkage
of electronic safety-related switching outputs").