Diagnostics and troubleshooting
Leuze electronic RSL 430 99
Diagnostic
ID
Diagnostic message Measure
E0588 Optics cover is soiled. Clean the optics cover.
I0604 Optics cover is soiled. Clean the optics cover as soon as possible.
Sensor is still in safety mode.
P0653 Safety configuration is not compatible: pro-
tective/warning field radius too large.
Swap out the safety sensor or change the
configuration. The type of safety sensor must
be the same as the type stored in the connec-
tion unit or in the Sensor Studio software.
P0654 Field pair changeover is not performed in
accordance with the specifications config-
ured in the safety sensor: field pair not de-
fined.
Check the wiring of function inputs F1toF10
and that the parameter settings in the configu-
ration are correct.
I0660 Field pair changeover is not performed in
accordance with the specifications config-
ured in the safety sensor: no field pair acti-
vated at system start.
Check the wiring of function inputs F1toF10
and that the parameter settings in the configu-
ration are correct.
U0661 Safety-related switching outputs (OSSDs)
cannot be switched: short circuit with 0V,
+24VDC or between OSSDs.
Check the wiring of the OSSDs.
I0719 Timeout of signals RES1 or RES2 (acknowl-
edgment button, start/restart).
Check the wiring of inputs RES1 and RES2.
The time specifications for start/restart must
be observed.
P0747 Safety configuration is not compatible: pro-
tective/warning field radius too small.
Change the dimensions and contour of the
protective field in the configuration. The mini-
mum range of the protective field must be ob-
served.
I0825 Simulation mode has been activated. The safety-related switching outputs (OSSDs)
have been switched off.
I0826 Simulation mode has been deactivated. Safety sensor is again in safety mode.
CAUTION!
Be aware of potential hazards which can oc-
cur when the machine is started up!
I0859 Configuration was reset. +24V detected at RES input after switch-on.
The communication parameters were reset to
default values.
I1004 Field violation due to glare.
(With switch-off of the OSSDs)
Mount the safety sensor so that the light
source does not hit the outlet disc directly.
I1005 Dazzled RSL.
(Without switch-off of the OSSDs)
Mount the safety sensor so that the light
source does not hit the outlet disc directly.
F.... The monitoring functions have detected an
internal error.
Create the service file (see chapter 4.5.5 "DI-
AGNOSIS") and contact the Leuze electronic
customer service (see chapter 14 "Service
and support").