2. Information on start-up, deinstallation and operation
Before installation, deinstallation, or troubleshooting:
• Stop the actuator/lifting column.
• Switch off the power supply or pull out the mains plug and pull out the plug to the actuator/lifting column.
• Relieve the actuator/lifting column of any loads, which may be released during the work.
Before start-up:
• Make sure that the system has been installed as instructed in this User Manual.
• The individual parts (actuator/lifting column/hand controls etc.) must be connected before the control box is connected to the mains.
• Make sure that the mains voltage to be connected to the product or the system is the one stated on the label.
• The equipment can be moved freely over the whole working area of the actuator/lifting column.
• Check correct function after mounting.
• The actuator/lifting column must not be loaded in excess of the values indicated in the specifications on the product label.
• The duty cycle noted on the product label must always be observed. Otherwise there is a risk of product damage. Exceeding the duty cycle will result
in a dramatic reduction of the system lifetime.
Unless specified otherwise on the product label, the duty cycle is max. 10%, max. 2 minutes in use followed by 18 minutes not in use.
• The actuator/lifting column system may only be used in an environment corresponding to the IP rating of the system. LINAK products are marked
with the actual IP rating on the label.
• If any individual parts are suspected to be damaged, do not install the parts, but return them for inspection/service.
During operation:
• Check for unusual sounds and irregular movement. Stop the actuator/lifting column immediately if anything unusual is observed.
• If the control box makes unusual noises or smells, switch off the mains voltage immediately and the external battery, if any.
• Take care that the cables are not damaged.