Operating mode Fault Cause Remedy
General Liquid leaks from the
housingofbasicow
meter
Seal defective Replace seal
Hairline cracks in
housing and/or on
screw connection
due to mechanical
inuences
Check installation conditions
for mechanical stresses and
correct them
Screw connection not
tightened securely
Check that screw connections
are secure
Operating pressure
exceeded, pressure
surges e.g. due to
water hammer
Check pressure conditions
Inadequate chemical
resistance
Contact manufacturer
Separate
installation of
the modules
Occasional
transmission errors
Display OK, but
operator inputs
impossible
Data line exposed
to strong
electromagnetic
elds(large
machines, power
cables, etc.)
Data line must be shielded
against electromagnetic
interference
Data line defective Check data line for damage
andsecuretofplug
connection
73
0698-651 Operating unit - 04/2021
en