Maintenance work on the carrier
7.4 Fuel system
7 - 28 3 302 744 en Maintenance manual
GMK5250L
09.03.2018
7.4.1 Draining off water from fuel filter 1
Spare parts and
tools
– Receptacle, approx. 5 l (1.5 gal); à p. 2 - 4.
Prerequisites – The truck crane must be level and on outriggers; à Operating manual.
– The main boom must be fully raised; à Operating manual.
– The engine must be switched off and secured against unauthorised use;
à p. 2 - 3.
Draining off water
• Place a receptacle underneath the filter.
• Open the valve (1).
• If the consumable that emerges is clean,
close the valve by hand.
• Remove the receptacle and properly dis-
pose of the drained consumable.
D
O
Risk of environmental damage due to leaking consumables.
Always let consumables drain into suitable receptacles. Wipe up any con-
sumables that have leaked.
Store/dispose of consumables and any soaked equipment properly.
Ask about the applicable regulations.

Table of Contents

Other manuals for Manitowoc Grove GMK 5250L

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc Grove GMK 5250L and is the answer not in the manual?

Manitowoc Grove GMK 5250L Specifications

General IconGeneral
BrandManitowoc
ModelGrove GMK 5250L
CategoryConstruction Equipment
LanguageEnglish

Related product manuals