Maintenance work on the carrier
7.5 Exhaust system with exhaust emission control
09.03.2018
Maintenance manual 3 302 744 en 7 - 35
GMK5250L
Filling up • Find out about filling up in the operating manual and note the warnings;
à Operating manual.
• Fill the AdBlue tank via the filler neck (1) and
close it using the cap.
• Check the level on the gauges (2) and (3) in
the driver's cab;
à p. 7 - 34.
7.5.3 Check the exhaust system for external damage
Spare parts and
tools
Prerequisites – The engine must be switched off and secured against unauthorised use;
à p. 2 - 3.
– The engine and the exhaust system must be cool.
s
G
Danger of scalding due to ammonia vapours.
Ammonia vapour can escape if the AdBlue tank is opened when the outside
temperature is high. Ammonia vapours can irritate mucous membranes,
skin and eyes.
Ensure that there is adequate fresh air supply and do not breathe in the
escaping ammonia vapours.
M 1
Designation Quantity GROVE part no.
Exhaust silencer with SCR catalytic
converter
(SCR = Selective Catalytic Reduction)
(with diesel particulate filter)
1 03140048

Table of Contents

Other manuals for Manitowoc Grove GMK 5250L

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc Grove GMK 5250L and is the answer not in the manual?

Manitowoc Grove GMK 5250L Specifications

General IconGeneral
BrandManitowoc
ModelGrove GMK 5250L
CategoryConstruction Equipment
LanguageEnglish

Related product manuals