Maintenance work on the carrier
7.18 Air conditioning system
09.03.2018
Maintenance manual 3 302 744 en 7 - 131
GMK5250L
7.18 Air conditioning system
7.18.1 Checking the air conditioning system
• Switch on the air-conditioning system; à Operating manual.
• Check that cooling takes place. If it does not, the air conditioning system
is defective.
• Switch the air conditioning system off.
If the air conditioning system is defective
• Do not start it up again to avoid further damage.
Have the air-conditioning system repaired as soon as possible by Manitowoc
Crane Care
or an authorised GROVE dealer or an authorised specialist work-
shop.
7.18.2 Checking hoses
• Check all refrigerant hoses for damage and areas of wear.
Have damaged hoses checked by Manitowoc Crane Care or an authorised
GROVE dealer or an authorised specialist workshop only.
M 1
M 6
G
Risk of burns due to escaping refrigerant.
Wear suitable safety glasses and gloves when checking the hoses and con-
nections.
This will prevent injury from suddenly escaping refrigerant. Seek medical
attention if the skin or eyes come into contact with the refrigerant.

Table of Contents

Other manuals for Manitowoc Grove GMK 5250L

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc Grove GMK 5250L and is the answer not in the manual?

Manitowoc Grove GMK 5250L Specifications

General IconGeneral
BrandManitowoc
ModelGrove GMK 5250L
CategoryConstruction Equipment
LanguageEnglish

Related product manuals